Seitenansicht 0
090314 ESPR.BODYA 5056.201
33333
INSTALER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these
instructions is not followed exactly a fire or
explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical Switch.
Do not use any phone in your building.
Immediately call your gas supplier
from a neighbour’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas supplier
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an
aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with
other gases unless a certified kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
LINEAR GAS FIREPLACE
INSTALLATION AND
OPERATING INSTRUCTIONS
MODEL: ESPRIT
ESPR.BODYA
ZERO CLEARANCE FIREPLACE
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - WHAT TO DO IF YOU SMELL GAS

090314 ESPR.BODYA 5056.201 33333 INSTALER: Leave

Seite 2

10 OWNER’S INFORMATION Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the s

Seite 3 - Table of Contents

11 OWNER’S INFORMATION ROOM THERMOSTAT (Transmitter Operation) The Remote Control can operate as a room thermostat. The thermostat can be set

Seite 4 - Caution

12 OWNER’S INFORMATION Continuous Pilot/Intermittent Pilot (CPI/IPI) selection With the system in "OFF" position press the Mode Key

Seite 5

13 OWNER’S INFORMATION KEY LOCK This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE a

Seite 6

14 OWNER’S INFORMATION DIMENSIONAL DRAWINGS Fig. 23: PROFLAME Transmitter dimensional drawing

Seite 7 - Remote Control Operation

15 OWNER’S INFORMATION Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing applianc

Seite 8 - Technical Data

16 OWNER’S INFORMATION c) Check that the vent pipe and vent terminal are open and free from blockage or debris. The flow of combustion and

Seite 9 - Wall mounting

17 OWNER’S INFORMATION Lighting Instructions

Seite 10 - Display

18 INSTALLER INFORMATION Fireplace Dimensions Fig. 24: Fireplace Dimensions Fig. 25: Framing The installation must conform with local codes

Seite 11

19 INSTALLER INFORMATION Fig. 26: Framing At The Corner Fig. 27: Minimum Clearance Corner Framing

Seite 12 - Figure 16

2 Important Note for the Commonwealth of Massachusetts: From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizonta

Seite 13 - Figure 22

20 INSTALLER INFORMATION Clearances to Combustibles Minimum Clearance to Combustible Materials ENCLOSED SIDE WALL 1.75" ENCLOSED BACK

Seite 14 - DIMENSIONAL DRAWINGS

21 INSTALLER INFORMATION Figure 30: Common Installation Location Locating the Fireplace In planning the installation for the fireplace, it is nec

Seite 15 - Maintenance

22 INSTALLER INFORMATION Installation 1. Fasten the surround base to the fireplace using supplied screws and mounting holes located along the inne

Seite 16 - CAUTION:

23 INSTALLER INFORMATION Venting Note: The intake damper positions specified in this chart were set in a controlled te

Seite 17 - Lighting Instructions

24 INSTALLER INFORMATION This fireplace is certified for use with 4” x 6-5/8”coaxial venting components only. It is permitted to only use cert

Seite 18 - Fireplace Dimensions

25 INSTALLER INFORMATION NOTE: Mixing venting components from different manufacturers is inadvisable. Venting Components Figure 1: 4”x6-5/8&q

Seite 19 - Corner Framing

26 INSTALLER INFORMATION Plumbing and Electrical Figure 37: Gas Connection Electrical connection Open the access pa

Seite 20 - Clearances to Combustibles

27 INSTALLER INFORMATION Servicing of the appliance can be performed from the front of the unit by removing the door and the burner tray from th

Seite 21 - Locating the Fireplace

28 INSTALLER INFORMATION Gas Pressure Testing Procedure Note: To test the gas pressure, turn off the gas supply to the appliance before loosenin

Seite 22 - Installation

29 INSTALLER INFORMATION Propane Conversion Before starting the conversion make sure to shut off the gas supply to the unit and allow fireplac

Seite 23 - Venting

3 Table of Contents Caution 4 Safety 5 Owners Information First Fire 6 Remote Control Operation

Seite 24

30 INSTALLER INFORMATION Door Installation/Removal Installation 1. Place the door in the slot at the bottom of the firebox opening. 2. Hold

Seite 25 - Venting Components

31 INSTALLER INFORMATION Figure 46: Back Panel Figure 47: Side Panel Figure 48: Baffle Mounts Figure 45: Panel Set Fan removal before fireplace

Seite 26 - Plumbing and Electrical

32 INSTALLER INFORMATION Figure 51: Ember Placement Figure 49: Burner Tray Burner and Tray Installation / Removal Burner Tray Installation /

Seite 27 - Gas pressure

33 INSTALLER INFORMATION Log Set Installation / Removal Figure 53: Two Rear Logs Figure 54: Rear Log Set Figure 55: Left Side Log Figure 56: Fro

Seite 28 - Pilot Adjustment

34 INSTALLER INFORMATION Glass Burner Kit Installation / Removal Glass Installation To install the glass, evenly spread a thin layer of crushed

Seite 29 - Propane Conversion

35 INSTALLER INFORMATION Intake Air Damper Installation The Esprit fireplaces come with the damper that can limit the

Seite 30 - Fan Installation / Removal

36 INSTALLER INFORMATION ESPRIT LINEAR GAS FIREPLACE SALES CODES UNIT ESPRIT LINEAR GAS FIREPLACE ...

Seite 31 - Panel Installation / Removal

37 INSTALLER INFORMATION Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause

Seite 32 - Embers Placement

38 INSTALLER INFORMATION NOTES: __________________________________________________________________________________________________________________

Seite 33

39 INSTALLER INFORMATION

Seite 34 - Glass Installation

4 FOR YOUR SAFETY - Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual.

Seite 35

Technical support: 1-250-748-1184 Web site: www. pacificenergy.net 2975 Allenby Rd., Duncan, BC V9l 6V8

Seite 36

5  Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies.  Children

Seite 37 - Wiring Diagram

6 OWNER’S INFORMATION Congratulations on your purchase of a Pacific Energy Gas Fireplace. Your fireplace has been professionally installed by: Deal

Seite 38 - Installation Notes

7 OWNER’S INFORMATION ` Remote Control O

Seite 39

8 OWNER’S INFORMATION Technical Data

Seite 40

9 OWNER’S INFORMATION

Kommentare zu diesen Handbüchern